西亚试剂:Clathrate nanostructures for mass spectrometry
发布时间:2025-12-26
Clathrate nanostructures for mass spectrometry
Trent R. Northen1,2,6, Oscar Yanes1,2,6, Michael T. Northen4, Dena Marrinucci3, Winnie Uritboonthai1,2, Junefredo Apon1,2, Stephen L. Golledge5, Anders Nordström1,2 & Gary Siuzdak1,2,6
- Department of Molecular Biology,
- Scripps Center for Mass Spectrometry,
- Department of Cell Biology, The Scripps Research Institute, La Jolla, California 92037, USA
- Materials Department, University of California at Santa Barbara, Santa Barbara, California 93106, USA
- CAMCOR Surface Analysis Facility at the University of Oregon, Eugene, Oregon 97403, USA
- These authors contributed equally to this work.
Correspondence to: Gary Siuzdak1,2,6 Correspondence and requests for materials should be addressed to G.S. (Email: siuzdak@scripps.edu).
The ability of mass spectrometry to generate intact biomolecular ions efficiently in the gas phase has led to its widespread application in metabolomics1, proteomics2, biological imaging3, biomarker discovery4 and clinical assays (namely neonatal screens5). Matrix-assisted laser desorption/ionization6, 7 (MALDI) and electrospray ionization8 have been at the forefront of these developments. However, matrix application complicates the use of MALDI for cellular, tissue, biofluid and microarray analysis and can limit the spatial resolution because of the matrix crystal size9 (typically more than 10
m), sensitivity and detection of small compounds (less than 500 Da). Secondary-ion mass spectrometry10 has extremely high lateral resolution (100 nm) and has found biological applications11, 12 although the energetic desorption/ionization is a limitation owing to molecular fragmentation. Here we introduce nanostructure-initiator mass spectrometry (NIMS), a tool for spatially defined mass analysis. NIMS uses 'initiator' molecules trapped in nanostructured surfaces or 'clathrates' to release and ionize intact molecules adsorbed on the surface. This surface responds to both ion and laser irradiation. The lateral resolution (ion-NIMS about 150 nm), sensitivity, matrix-free and reduced fragmentation of NIMS allows direct characterization of peptide microarrays, direct mass analysis of single cells, tissue imaging, and direct characterization of blood and urine.
- 以上资料由西亚试剂:http://www.xiyashiji.com/ 提供此产品的详细信息如密度,含量,分子式,分子量等均可在西亚官网查询
- 相关产品如溴化汞硝酸亚汞氯化亚汞乙酸苯汞氯化钾汞 碘化汞钾硫氰酸汞硫酸亚汞氧化汞氯化汞碘化汞硝酸汞三氯氧磷三氯化磷碘甲烷二碘甲烷三碘甲烷三氟碘甲烷氘代碘甲烷碘乙烷1,2-二碘乙烷甲酸铷碘化铷溴化铷铬酸铷硫酸铷氟化铷硝酸铷氯化铷碳酸铷硫酸镱 碳酸镱氯化镱硝酸镱氧化镱等均有销售.欢迎订购
下一篇:西亚试剂 :Structure of the L Protein of Vesicular Stomatitis Viru



鲁ICP备20015914号-4